Esta buscando: Filtros de precolumnas

Precolumn filters are essential for protecting HPLC columns against particulate matter which can accumulate on the column frit, leading to split peaks and high backpressure. Sources of particles include mobile phases (especially when buffers are mixed with organic solvents), leaking pump and injector seals, and samples. Precolumn filters are also useful because changing the column frit is extremely difficult to do without disturbing the column packing, whereas changing the precolumn filter’s frit is easy, providing relatively inexpensive insurance against column damage.

Precolumn filters are essential for protecting HPLC columns against particulate matter which can accumulate on the column frit, leading to split peaks and high backpressure. Sources of particles include mobile phases (especially when buffers are mixed with organic solvents), leaking pump and injector seals, and samples. Precolumn filters are also useful because changing the column frit is extremely difficult to do without disturbing the column packing, whereas changing the precolumn filter’s frit is easy, providing relatively inexpensive insurance against column damage.


192  results were found

Sort Results

SearchResultCount:"192"
Descripción: Upchurch Scientific®, A-700 replacement frit, PEEK, Porosidad: 2,0 µm, Grosor: 1,6 mm, Frit Ø ext.: 1,6 mm, Sinterizado, el volumen: 0,7 µl, Anillo Ø ext.: 6,4 mm, Material anillo: PCTFE
Numero del catalogo: 554-1981
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, A-722 semi-prep frit, Porosidad: 10,0 µm, Grosor: 1,8 mm, Frit Ø ext.: 5,0 mm, Sinterizado, el volumen: 9,9 µl, Materiales sinterizados: PEEK, Anillo Ø ext.: 6,4 mm, Material anillo: PCTFE
Numero del catalogo: 554-3055
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, A-720 semi-prep frit, Porosidad: 10,0 µm, Grosor: 1,8 mm, Frit Ø ext.: 3,2 mm, Sinterizado, el volumen: 4,2 µl, Materiales sinterizados: PEEK, Anillo Ø ext.: 6,4 mm, Material anillo: PCTFE
Numero del catalogo: 554-3053
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, M-555-1 precolumn MicroFilter assembly, for 1/16" OD tubing, Porosidad: 2,0 µm, Volumen barrido: 0,5 µl, Frit Ø ext.: 0,9 mm, Materiales sinterizados: Acero inoxidable, Anillo Ø ext.: 4,8 mm, Material anillo: PEEK
Numero del catalogo: UPCHM-555-1
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, A-710 frit, Porosidad: 2,0 µm, Grosor: 1,6 mm, Frit Ø ext.: 3,2 mm, Sinterizado, el volumen: 3,0 µl, Materiales sinterizados: PEEK, Anillo Ø ext.: 5,1 mm, Material anillo: PCTFE
Numero del catalogo: UPCHA-710
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, A-702 frit, Porosidad: 2,0 µm, Grosor: 1,6 mm, Frit Ø ext.: 2,3 mm, Sinterizado, el volumen: 1,7 µl, Materiales sinterizados: PEEK, Anillo Ø ext.: 6,4 mm, Material anillo: PCTFE
Numero del catalogo: UPCHA-702
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, A-707 frit, Porosidad: 0,5 µm, Grosor: 1,6 mm, Frit Ø ext.: 5,0 mm, Sinterizado, el volumen: 6,1 µl, Materiales sinterizados: PEEK, Anillo Ø ext.: 6,4 mm, Material anillo: PCTFE
Numero del catalogo: 554-3051
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, M-560-01 precolumn MicroFilter body, for 1/16" OD tubing, Porosidad: 0,5 µm, Volumen barrido: 0,5 µl, Frit Ø ext.: 1,1 mm, Materiales sinterizados: PEEK, Anillo Ø ext.: 4,8 mm, Material anillo: PCTFE
Numero del catalogo: 554-3086
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, C-128-31 frit, Porosidad: 0,5 µm, Grosor: 0,71 mm, Frit Ø ext.: 1,0 mm, Sinterizado, el volumen: 0,1 µl, Materiales sinterizados: Acero inoxidable, Anillo Ø ext.: 3,17 mm, Material anillo: PEEK
Numero del catalogo: UPCHC-128-31
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, C-425 frit, Porosidad: 0,5 µm, Grosor: 0,71 mm, Frit Ø ext.: 1,0 mm, Sinterizado, el volumen: 0,1 µl, Materiales sinterizados: Acero inoxidable, Anillo Ø ext.: 4,87 mm, Material anillo: PCTFE
Numero del catalogo: UPCHC-425
UOM: 1 * 25 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, A-418 frit, Porosidad: 0,5 µm, Grosor: 1,57 mm, Frit Ø ext.: 1,6 mm, Sinterizado, el volumen: 0,6 µl, Materiales sinterizados: Acero inoxidable, Anillo Ø ext.: 5,08 mm, Material anillo: PCTFE
Numero del catalogo: UPCHA-418
UOM: 1 * 25 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, C-140-30 frit, Porosidad: 0,5 µm, Grosor: 1,57 mm, Frit Ø ext.: 4,8 mm, Sinterizado, el volumen: 6,5 µl, Materiales sinterizados: Acero inoxidable, Anillo Ø ext.: 6,45 mm, Material anillo: PCTFE
Numero del catalogo: UPCHC-140-30
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Upchurch Scientific®, C-409 frit, Porosidad: 0,5 µm, Grosor: 0,71 mm, Frit Ø ext.: 1,0 mm, Sinterizado, el volumen: 0,1 µl, Materiales sinterizados: Acero inoxidable, Anillo Ø ext.: 1,57 mm, Material anillo: PCTFE
Numero del catalogo: UPCHC-409
UOM: 1 * 1 UN
Proveedor: UPCHURCH SCIENTIFIC


Descripción: Precolumn filter kit, max.flow rate 30 ml/min, PEEK, Porosidad: 0,5 µm, <350 bar, Volumen barrido: 11,5 µl, Materiales sinterizados: Titanio
Numero del catalogo: JOURJR-68258
UOM: 1 * 1 UN
Proveedor: VICI JOUR RESEARCH


Descripción: Precolumn filter kit, max.flow rate 30 ml/min, PEEK, Porosidad: 2,0 µm, <350 bar, Volumen barrido: 13,85 µl, Materiales sinterizados: Titanio
Numero del catalogo: JOURJR-68262
UOM: 1 * 1 UN
Proveedor: VICI JOUR RESEARCH


Descripción: Replacement frit, Porosidad: 10,0 µm, Grosor: 1,50 mm, Frit Ø ext.: 4,60 mm, Sinterizado, el volumen: 11,31 µl, Materiales sinterizados: PE, Anillo Ø ext.: 6,35 mm
Numero del catalogo: JOURJR-1151-10P-5
UOM: 1 * 5 UN
Proveedor: VICI JOUR RESEARCH


145 - 160 of 192