Esta buscando: Histopaque®


7  results were found

SearchResultCount:"7"

Sort Results

Vista lista Vista Extendida (Nueva)

Valore los resultados de su búsqueda

Numero del catalogo: (A6929-40X3ML)
Proveedor: SIGMA ALDRICH MICROSCOPY
Descripción: ACCUSPIN System-Histopaque-1077 products are intended for use in the isolation of lymphocytes and other mononuclear cells. The separation medium, Histopaque-1077, is a sterile-filtered, endotoxin-tested solution of polysucrose and sodium diatrizoate, adjusted to a density of 1,077 g/ml. ACCUSPIN System-HISTOPAQUE-1077 employs γ-irradiated 12mL polypropylene centrifuge tubes specially designed with two chambers separated by a porous high-density polyethylene barrier ('frit'). Each tube is aseptically filled with 3 mL of Histopaque 1077. Each tube will separate 3 to 6 ml of anticoagulated blood.
UOM: 1 * 1 C/U


Numero del catalogo: (A7054-12X15ML)
Proveedor: SIGMA ALDRICH MICROSCOPY
Descripción: ACCUSPIN System-Histopaque-1077 products are intended for use in the isolation of lymphocytes and other mononuclear cells. The separation medium, Histopaque-1077, is a sterile-filtered, endotoxin-tested solution of polysucrose and sodium diatrizoate, adjusted to a density of 1,077 g/ml. ACCUSPIN System-HISTOPAQUE-1077 employs γ-irradiated 50 mL polypropylene centrifuge tubes specially designed with two chambers separated by a porous high-density polyethylene barrier ('frit'). Each tube is aseptically filled with 15 ml of Histopaque 1077. Each tube will separate 15-30 mL of anticoagulated blood.
UOM: 1 * 1 C/U


Proveedor: SIGMA ALDRICH MICROSCOPY
Descripción: Histopaque-1077 is a sterile, endotoxin tested, ready-to-use medium. The Histopaque composition includes polysucrose and sodium diatrizoate, adjusted to a density of 1,077 g/ml. This ready-to-use medium facilitates rapid recovery of viable lymphocytes and other mononuclear cells from small volumes of whole blood or bone marrow.

Proveedor: SIGMA ALDRICH MICROSCOPY
Descripción: Histopaque®-1119 is a sterile, endotoxin tested, ready-to-use medium. This solution consists of polysucrose and sodium diatrizoate, adjusted to a density of 1,119 g/ml and pH 8,8 to 9,0.

Numero del catalogo: (A0561-100X15ML)
Proveedor: SIGMA ALDRICH MICROSCOPY
Descripción: ACCUSPIN System-Histopaque-1077 products are intended for use in the isolation of lymphocytes and other mononuclear cells. The separation medium, Histopaque-1077, is a sterile-filtered, endotoxin-tested solution of polysucrose and sodium diatrizoate, adjusted to a density of 1,077 g/ml. ACCUSPIN System-HISTOPAQUE-1077 employs γ-irradiated 50 mL polypropylene centrifuge tubes specially designed with two chambers separated by a porous high-density polyethylene barrier ('frit'). Each tube is aseptically filled with 15 ml of Histopaque 1077. Each tube will separate 15 to 30 ml of anticoagulated blood.
UOM: 1 * 1 UN


Proveedor: SIGMA ALDRICH MICROSCOPY
Descripción: Histopaque®-1083 is a solution containing polysucrose and sodium diatrizoate, adjusted to a density of 1,083 g/ml. It facilitates the recovery of viable mononuclear cells from small volumes of blood of rats, mice, and other small mammals. Histopaque®-1083 has been used for the isolation of mononuclear cells and leukocytes from rat peripheral blood.

Numero del catalogo: (ICNA0219083780)
Proveedor: MP Biomedicals
Descripción: Histopaque™1077 is a solution of polysaccharide (Ficoll-400) and a radiopaque contrast medium (sodium diatrizoate).
UOM: 1 * 100 mL


Consulta de precio
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta. Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta.
Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto ha sido bloqueado por su organización. Por favor, pónganse en contacto con su departamento de compras para obtener más información.
El producto original ya no está disponible. Su sustituto se muestra a continuación.
El producto(s) marcados con este símbolo están descatalogados - se venden hasta acabar stock. Pueden encontrar alternativas buscando con el número de catálogo VWR listado arriba. Si necesita más ayuda, por favor llame al Servicio de atención al cliente de VWR al 902.222.897.
1 - 7 of 7
no targeter for Bottom