Esta buscando: Sistemas verticales de electroforesis en gel

Vertical gel electrophoresis systems are primarily used for nucleic acid or protein sequencing. Achieve precise voltage control using this format that forces charged molecules to travel through the casted gel since it is the only buffer chamber connection. The low current used with the vertical gel systems does not require buffer to be recirculated. With strong clamps to guarantee the assembly stays in an upright position, the equipment facilitates fast gel runs with even cooling resulting in distinct bands.

Vertical gel electrophoresis systems are primarily used for nucleic acid or protein sequencing. Achieve precise voltage control using this format that forces charged molecules to travel through the casted gel since it is the only buffer chamber connection. The low current used with the vertical gel systems does not require buffer to be recirculated. With strong clamps to guarantee the assembly stays in an upright position, the equipment facilitates fast gel runs with even cooling resulting in distinct bands.


21  results were found

SearchResultCount:"21"

Sort Results

Vista lista Vista Extendida (Nueva)

Valore los resultados de su búsqueda

Numero del catalogo: (730-0263)
Proveedor: THERMO OWL SCIENTIFIC
Descripción: The Owl™ P10DS dual gel system casts and runs one or two 20×20 cm gels in the upper buffer chamber. The larger size cassette allows the maximum number of samples and separation length. The system is ideal for second dimension protocols of 2-D electrophoresis applications.
UOM: 1 * 1 UN


Numero del catalogo: (80-6418-77)
Proveedor: Cytiva
Descripción: The simple, modular design of miniVE vertical electrophoresis system consolidates all the small parts for electrophoresis and blotting into one convenient unit. Uniform gel temperature is maintained with the tank-style lower buffer chamber. A full tank stabilises the temperature so that lanes are straight and bands are flat. The blot module will accept two gel/membrane stacks simultaneously. The lower buffer chamber is designed to hold two blot modules, allowing four gels to be blotted at once.
UOM: 1 * 1 UN


Numero del catalogo: (PR52-L)
Proveedor: Cytiva
Descripción: Vertical gel electrophoresis system, accessory, Replacement tray liner, 290×290 mm
UOM: 1 * 1 UN


Numero del catalogo: (732-1427)
Proveedor: EDVOTEK
Descripción: Designed for separation of proteins on polyacrylamide gels, the MV10 unit holds one 9×19 cm gel cassette and can accommodate most pre-cast or self-made gels.
UOM: 1 * 1 UN


Numero del catalogo: (80-6479-57)
Proveedor: Cytiva
Descripción: The key to outstanding, reproducible electrophoresis results is temperature control. Gels unequally cooled on their two faces produce slanted bands appearing as broad or double bands in stained gels. SE 600 Ruby™ ensures uniform heat in gels because, firstly, the gels are completely immersed in the lower buffer for uniform heat transfer and, secondly, a standard magnetic stirrer circulates buffer around the vertically suspended heat exchanger to maintain homogeneous lower buffer temperature. The ergonomically designed SE 600 Ruby™ provides two built-in side handles, which facilitates carrying and handling.
UOM: 1 * 1 UN


Consulta de precio
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta. Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta.
Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto ha sido bloqueado por su organización. Por favor, pónganse en contacto con su departamento de compras para obtener más información.
El producto original ya no está disponible. Su sustituto se muestra a continuación.
El producto(s) marcados con este símbolo están descatalogados - se venden hasta acabar stock. Pueden encontrar alternativas buscando con el número de catálogo VWR listado arriba. Si necesita más ayuda, por favor llame al Servicio de atención al cliente de VWR al 902.222.897.
17 - 21 of 21
no targeter for Bottom