Esta buscando: Sistemas completos para HPLC

Sophisticated complete HPLC systems offer an easy and improved liquid chromatography method for separating mixture compounds essential for further quantification or identification analyses. Instead of the sample traveling through the column by gravitational means, this equipment utilizes a forced air pressure push to achieve faster results. Pumps maintain a consistent flow rate while ultra-sensitive detectors assist with accurate retention times. For better separations, the complete HPLC systems allow pre-packed stationary phase materials with smaller particle sizes.

Sophisticated complete HPLC systems offer an easy and improved liquid chromatography method for separating mixture compounds essential for further quantification or identification analyses. Instead of the sample traveling through the column by gravitational means, this equipment utilizes a forced air pressure push to achieve faster results. Pumps maintain a consistent flow rate while ultra-sensitive detectors assist with accurate retention times. For better separations, the complete HPLC systems allow pre-packed stationary phase materials with smaller particle sizes.


45  results were found

Sort Results

SearchResultCount:"45"
Descripción: Chromaster Plus HPLC CM5310 Advanced Spec -column oven with 0,5 m e-Line cable, power cable and integrated 600 bar VICI switching valve
Numero del catalogo: 903-0367
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus HPLC complete 600 bar system with CM5160 auto purge quaternary gradient pump, CM5260 standard loop autosampler, CM5310 column oven and CM5420 variable wavelength UV-VIS detector, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial rack and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. 5410 variable wavelength UV detector with 13 µl, 10 mm flow cell, double beam ratio photometric system with Hg lamp for checking wavelength. Wavelength range: 190 - 600 nm. Chromaster System Manager control and data acquisition software included. All cables and interface board included
Numero del catalogo: 903-0396
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5280 direct injection autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5280 autosampler with 200 vial rack and direct injection with needle integrated into sample loop, 100 µl syringe for accurate sample metering. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. All cables and interface board included
Numero del catalogo: 903-0359
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5260 thermostat standard loop autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial peltier thermostatted rack from 1 to 45 °C and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. All cables and interface board included
Numero del catalogo: 903-0342
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5260 standard loop autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial rack and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. All cables and interface board included
Numero del catalogo: 903-0343
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus HPLC complete 600 bar system with CM5160 manual purge quaternary gradient pump, CM5260 standard loop autosampler, CM5310 column oven and CM5410 variable wavelength UV detector, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial rack and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. 5410 variable wavelength UV detector with 13 µl, 10 mm flow cell, double beam ratio photometric system with Hg lamp for checking wavelength. Wavelength range: 190 - 600 nm. Chromaster System Manager control and data acquisition software included. All cables and interface board included
Numero del catalogo: 903-0337
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus HPLC complete 600 bar system for standard bore columns with CM5160 manual purge quaternary gradient pump, CM5260 thermostat standard loop autosampler, CM5310 column oven, CM5430 diode array detector, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial peltier thermostatted rack from 1 to 45 °C and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. 5430 diode array detector with 1.024 bit PDA, auto wavelength check, range 190 - 900 mm with 13 µl, 10 mm cell. All cables and interface board included
Numero del catalogo: 903-0355
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5280 thermostat direct injection autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5280 autosampler with 200 vial peltier rack, 4 to 35 °C, and direct injection with needle integrated into sample loop, 100 µl syringe for accurate sample metering. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. All cables and interface board included
Numero del catalogo: 903-0358
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Detector de UV Chromaster 5410, Low noise and low drift for high sensitivity detection with two-wavelength simultaneous measurement function. Automatic wavelength accuracy check with Hg lamp. D₂ Lamp wavelength range: 190 - 600 nm. Supplied with 13 µl cell, 10 mm path length. Other flow cell options available
Numero del catalogo: 903-0524
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Horno de columna Chromaster 5310, Temperature range 1 to 85 °C peltier heating and cooling block for excellent stability. Optional switching valves available. Column management system option available
Numero del catalogo: 903-0520
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus Basic UV CSA5HE package including CM5160 pump with manual purge valve, 600 bar, low pressure quaternary gradient unit, 6-channel degassing unit, CM5260 autosampler, CM5310 column oven, CM5410 UV detector, organiser, interface control board, ChromSwordAuto® 5 Hitachi Edition including CDS and Scout System, VWR®/Hitachi starter kit
Numero del catalogo: 903-0370
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus Professional DAD CSA5HE package including CM5160 pump with auto-purge valve. 600 bar, low pressure quaternary gradient unit, 6-channel degassing unit, user interface key pad, plunger wash pump, CM5260 autosampler with thermostat, CM6310 column oven, 6 column selector Rheodyne® valve, CM5430 DAD without flow cell, standard flow cell, organiser, interface control board
Numero del catalogo: 903-0372
UOM: 1 * 1 UN
Proveedor: VWR Collection


Descripción: Chromaster Plus Standard DAD CSA5HE package including CM5160 pump with manual purge valve. 600 bar, low pressure quaternary gradient unit, 6-channel degassing unit, user interface key pad, CM5260 autosampler with thermostat, 5310 column oven, 3-column selection Rheodyne® valve, CM5430 DAD without flow cell, standard flow cell, organiser, Interface Control Board, ChromSwordAuto® 5 Hitachi Edition including CDS and Scout System, VWR®/Hitachi starter kit
Numero del catalogo: 903-0371
UOM: 1 * 1 UN
Proveedor: VWR Collection


33 - 45 of 45