Esta buscando: JM+SEPARATIONS


5 008  results were found

SearchResultCount:"5008"

Sort Results

Vista lista Vista Extendida (Nueva)

Valore los resultados de su búsqueda

Numero del catalogo: (BOSSBS-5732R-A350)
Proveedor: Bioss
Descripción: Protein kinase which is involved in the control of centrosome separation and bipolar spindle formation in mitotic cells and chromatin condensation in meiotic cells. Regulates centrosome separation (essential for the formation of bipolar spindles and high-fidelity chromosome separation) by phosphorylating centrosomal proteins such as CROCC, CEP25 and NINL, resulting in their displacement from the centrosomes. Regulates kinetochore microtubule attachment stability in mitosis via phosphorylation of NDC8. Involved in regulation of mitotic checkpoint protein complex via phosphorylation of CDC2 and MAD2L1. Plays an active role in chromatin condensation during the first meiotic division through phosphorylation of HMGA2. Phosphorylates: PPP1CC; SGOL1; NECAB3 and NPM1. Essential for localization of MAD2L1 to kinetochore and MAPK1 and NPM1 to the centrosome. Isoform 1 phosphorylates and activates NEK11 in G1/S-arrested cells. Isoform 2, which is not present in the nucleolus, does not.
UOM: 1 * 100 µl


Proveedor: VWR Collection
Descripción: These HPTLC glass plates have an excellent separation efficiency due to an optimised particle size distribution.

Proveedor: Avantor
Descripción: Avantor® Hichrom Anion/S columns are based on 10 µm silica with quaternary ammonium ion-exchange groups. These columns are optimised for non-suppressed conductivity detection and are best suited for routine separations of chloride, bromide, nitrate and sulphate.

Proveedor: Avantor
Descripción: The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.

Proveedor: Avantor
Descripción: The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.

Proveedor: Avantor
Descripción: Avantor® ACE® UltraCore SuperPhenylHexyl solid-core (core-shell) particle columns are ideal for demanding MS work offering improved MS signal intensity and maximum MS response. These stainless steel columns combine high efficiency separations with low column back pressure. The Encapsulated Bonding Technology (EBT™) greatly increases the ligand coverage of the silica surface and effectively eliminates the effect of unbonded silanol groups on separations. This higher ligand coverage results in improved inertness, chromatographic performance and stability.

Proveedor: VWR Collection
Descripción: Designed for safe and secure transport of a specimen container and documentation, these 51 µm thick bags feature a pouch to keep the paperwork separate from the container. They have a self-sealing closure and are tamper evident.

Proveedor: Simport Scientific
Descripción: Ideal for cassette-labelling instruments since the covers are packed separately in the case. These biopsy cassettes, made of acetal polymer, are similar to the M517 series but are especially designed to hold biopsy specimens during the processing/embedding process as well as in storage cabinets.

Numero del catalogo: (BOSSBS-7732R-A555)
Proveedor: Bioss
Descripción: Stable cohesion between sister chromatids before anaphase and their timely separation during anaphase are critical for chromosome inheritance. In vertebrates, sister chromatid cohesion is released in 2 steps via distinct mechanisms. The first step involves phosphorylation of STAG1 (MIM 604358) or STAG2 (MIM 300826) in the cohesin complex. The second step involves cleavage of the cohesin subunit SCC1 (RAD21; MIM 606462) by ESPL1, or separase, which initiates the final separation of sister chromatids (Sun et al., 2009 [PubMed 19345191]).[supplied by OMIM, Nov 2010].
UOM: 1 * 100 µl


Proveedor: Avantor
Descripción: Avantor® ACE® UltraCore SuperC18 solid core (core shell) particle columns are ideal for demanding MS work offering improved MS signal intensity and maximum MS response. These stainless steel columns combine high efficiency separations with low column back pressure. The Encapsulated Bonding Technology (EBT™) greatly increases the ligand coverage of the silica surface and effectively eliminates the effect of unbonded silanol groups on separations. This higher ligand coverage results in improved inertness, chromatographic performance and stability.

Proveedor: Avantor
Descripción: Avantor® ACE® UltraCore SuperPhenylHexyl solid-core (core-shell) particle columns are ideal for demanding MS work offering improved MS signal intensity and maximum MS response. These stainless steel columns combine high efficiency separations with low column back pressure. The Encapsulated Bonding Technology (EBT™) greatly increases the ligand coverage of the silica surface and effectively eliminates the effect of unbonded silanol groups on separations. This higher ligand coverage results in improved inertness, chromatographic performance and stability.

Proveedor: Avantor
Descripción: Las columnas HPLC Avantor® Apollo utilizan sílice desactivada con base de alta pureza para realizar separaciones potentes.

Proveedor: Avantor
Descripción: Las columnas Vydac MS son un desarrollo posterior de Grace para la separación de biomoléculas por HPLC en fase reversa.

Numero del catalogo: (0217-1KG)
Proveedor: VWR Chemicals
Descripción: Non ionic detergent efficiently separate hydrophilic proteins from membrane spanning, hydrophobic proteins without altering biological activity.
UOM: 1 * 1 kg

FDS Certificados


Proveedor: VWR Collection
Descripción: The largest of the series, the Twin L can accommodate 20×20 cm gels for the simultaneous separation of up to 50 samples making this system ideally suited to either higher throughput or separating lower molecular weight samples. The system actively manages temperature build up with an efficient water cooling system and central aluminium ceramic plates for effective and safe long-term operation.

Proveedor: Trajan Scientific and Medical
Descripción: Ideal for separation of enantiomeric compounds found in natural products.

Consulta de precio
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta. Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta.
Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto ha sido bloqueado por su organización. Por favor, pónganse en contacto con su departamento de compras para obtener más información.
El producto original ya no está disponible. Su sustituto se muestra a continuación.
El producto(s) marcados con este símbolo están descatalogados - se venden hasta acabar stock. Pueden encontrar alternativas buscando con el número de catálogo VWR listado arriba. Si necesita más ayuda, por favor llame al Servicio de atención al cliente de VWR al 902.222.897.
193 - 208 of 5 008
no targeter for Bottom