Esta buscando: SMCC (N-Succinimidyl 4-(N-Maleimidomethyl)cyclohexanecarboxylate)


7  results were found

SearchResultCount:"7"

Sort Results

Vista lista Vista Extendida (Nueva)

Valore los resultados de su búsqueda

Numero del catalogo: (BC20)
Proveedor: G-Biosciences
Descripción: Succinimidyl 4-(N-maleimidomethyl) cyclohexane-1-carboxylate Heterobifunctional Cross Linkers.
UOM: 1 * 100 mg


Proveedor: TCI
Descripción: SMCC (N-Succinimidyl 4-(N-Maleimidomethyl)cyclohexanecarboxylate) ≥98.0% (by HPLC)

Nueva transparencia para los clientes europeos

¿Ha observado nuestra nueva visibilidad mejorada de la ubicación del stock en el paso de adquisición?

Más información

Mejora para las ubicaciones de stock

Proveedor: Apollo Scientific
Descripción: Primary amine and Sulphhydryl reactive, Enzyme antibody conjugation.

Proveedor: AAT BIOQUEST INC
Descripción: SMCC is a non-cleavable and membrane permeable crosslinker with a spacer arm of 8.3 Å. It contains an amine-reactive succinimidyl ester (SE) and a sulfhydryl-reactive maleimide group. NHS esters react with primary amines at pH 7 to 9 to form stable amide bonds. Maleimides react with sulfhydryl groups at pH 6.5 to 7.5 to form stable thioether bonds. The SE group of SMCC is reacted with lysine residues on the carrier protein, converting them to reactive maleimides. SMCC is a reagent that is widely used for generating stable maleimide-activated carrier proteins that can spontaneously react with sulfhydryls. Alternatively these relatively stable maleimide-activated intermediates may be lyophilized and stored for later conjugation to a hapten.

New Product

Numero del catalogo: (PIERA35394)
Proveedor: Thermo Fisher Scientific
Descripción: Thermo Scientific Pierce SMCC is a hetero-bifunctional crosslinker that contain N-hydroxysuccinimide (NHS) ester and maleimide groups that allow covalent conjugation of amine- and sulfhydryl-containing molecules. NHS esters react with primary amines at pH 7–9 to form amide bonds, while maleimides react with sulfhydryl groups at pH 6.5–7.5 to form stable thioether bonds. In aqueous solutions, NHS ester hydrolytic degradation is a competing reaction whose rate increases with pH. The maleimide group is more stable than the NHS-ester group, but will slowly hydrolyze and lose its reaction specificity for sulfhydryls at pH values > 7.5. For these reasons, conjugations with these crosslinkers are usually performed at pH 7.2–7.5, with the NHS ester (amine-targeted) reacted before or simultaneous with the maleimide (sulfhydryl-targeted) reaction.
UOM: 1 * 10 mg


Numero del catalogo: (PIER22360)
Proveedor: Thermo Fisher Scientific
Descripción: Thermo Scientific Pierce SMCC is a hetero-bifunctional crosslinker that contain N-hydroxysuccinimide (NHS) ester and maleimide groups that allow covalent conjugation of amine- and sulfhydryl-containing molecules. NHS esters react with primary amines at pH 7–9 to form amide bonds, while maleimides react with sulfhydryl groups at pH 6.5–7.5 to form stable thioether bonds. In aqueous solutions, NHS ester hydrolytic degradation is a competing reaction whose rate increases with pH. The maleimide group is more stable than the NHS-ester group, but will slowly hydrolyze and lose its reaction specificity for sulfhydryls at pH values > 7.5. For these reasons, conjugations with these crosslinkers are usually performed at pH 7.2–7.5, with the NHS ester (amine-targeted) reacted before or simultaneous with the maleimide (sulfhydryl-targeted) reaction.
UOM: 1 * 50 mg

MSDS Certificados


Numero del catalogo: (573114-100)
Proveedor: Merck Millipore (Calbiochem‎)
Descripción: Heterobifunctional reagent useful for enzyme labeling of antibodies and antibody fragments. Cross-links both a sulfhydryl group and a free amine group. Useful for sequential conjugation to minimize polymerization.
Reacts with primary amines and sulfhydryl groups.
UOM: 1 * 100 mg

Certificados


Consulta de precio
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
El stock para este material es limitada pero puede estar disponible en un almacén cerca de usted. Por favor, asegúrese de que ha iniciado sesión en la web para que el stock disponible se puede mostrar. Si el call sigue apareciendo y usted necesita ayuda, por favor llámenos al 902 222 897 o por email en webshop.es@avantorsciences.com.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta. Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto se trata de un artículo regulado sometido a normativa que restringe su venta.
Si procede, nos pondremos en contacto con usted para solicitarle la licencia o declaración de uso necesaria para poder proceder al suministro del producto.
Este producto ha sido bloqueado por su organización. Por favor, pónganse en contacto con su departamento de compras para obtener más información.
El producto original ya no está disponible. Su sustituto se muestra a continuación.
El producto(s) marcados con este símbolo están descatalogados - se venden hasta acabar stock. Pueden encontrar alternativas buscando con el número de catálogo VWR listado arriba. Si necesita más ayuda, por favor llame al Servicio de atención al cliente de VWR al 902.222.897.
1 - 7 of 7
no targeter for Bottom